When I did some research at the BFRC on the powerhouse I found that Ford switched back and forth on the top and side mounting of the cutout. Not all, but many field pole screws and mounting bracket screws were staked at the screwdriver slot to keep them from loosening. Examine the stakes for any tampering if you suspect it was pieced together from a mix of parts.
The field windings on the 5 brush had more wire than the 3 brush powerhouse, so when you connect a 6 volt battery charger to check the field coils you should have about 1 to 1 1/2 amps draw on the 5 brush field coils and 2 or a hair more on the 3 brush field coils.
Also a few mounting brackets have the FORD script on the front face near the middle of the bracket. I couldn't pin down any information on this and the script can be found on a few 3 and 5 brush powerhouse generators.
BTW, check all the pictures in "THE MODEL A FORD as HENRY BUILT IT" and you will see a Model A comming down the assembly line in November 1928 and it still has the tension bracket. Page 59 in my edition.