Blowing Starter Safety Fuse Help Please

31ASlant

Member
Any help would be much appreciated.
I’m working on a 30 Tudor
All stock. I have installed a tested generator and
Cutout. When I hook the battery cable up,
The generator cutout immediately closes the points
And since the vehicle isn’t running or ignition on,
It blows the safety fuse.
So basically it’s trying to motor the generator while everything is off.
Now if I attach the cutout without the 2 little screws on the generator body
It all works.
All I can think of is something off the harness from the coil and starter side is
Has power when it touches the batt connection on the cutout top.
 
Here’s a picture. If it helps.
 

Attachments

  • IMG_5108.jpg
    IMG_5108.jpg
    39.9 KB · Views: 311
I’m not sure about the cutout itself. I’m assuming it’s positive ground.
I don’t know if they made them another way
 
Any help would be much appreciated.
I’m working on a 30 Tudor
All stock. I have installed a tested generator and
Cutout. When I hook the battery cable up,
The generator cutout immediately closes the points
And since the vehicle isn’t running or ignition on,
It blows the safety fuse.
So basically it’s trying to motor the generator while everything is off.
Now if I attach the cutout without the 2 little screws on the generator body
It all works.
All I can think of is something off the harness from the coil and starter side is
Has power when it touches the batt connection on the cutout top.
you need a nylon or non-conducting washer between the cutout and two yellow wires.should not touch cutout.
 
Any help would be much appreciated.
I’m working on a 30 Tudor
All stock. I have installed a tested generator and
Cutout. When I hook the battery cable up,
The generator cutout immediately closes the points
And since the vehicle isn’t running or ignition on,
It blows the safety fuse.
So basically it’s trying to motor the generator while everything is off.
Now if I attach the cutout without the 2 little screws on the generator body
It all works.

All I can think of is something off the harness from the coil and starter side is
Has power when it touches the batt connection on the cutout top.
.
.
.

Maybe one of the small screws that mounts the cutout, is TOO long and is shorting one of the field coil wires.
 
Last edited:
Here is photo of what Gary WA is referring to>>>

Square part keeps washer in place and prevents shorts to the case cover.

Square part also centers the cover so the screw does not short on cover.

Photo from Berts website: www.modelastore.com

A-10563 GENERATOR CUTOUT INSULATORS- SET OF 2
 

Attachments

  • A10563- cutout insulator.jpg
    A10563- cutout insulator.jpg
    10.4 KB · Views: 11
Last edited:
Ok now I understand. So I’m basically putting 6 volts to the case of the cutout.
Is that why I’m burning fuses?
Thank you
 
Its the wrong cutout, its backwards and missing the proper insulators. I rebuild generators and refurbish original cutouts. I can provide you with a correct cutout. PM me if interested.
Steve
 

Attachments

  • 20240214_170130_copy_907x945.jpg
    20240214_170130_copy_907x945.jpg
    48.7 KB · Views: 61
Its the wrong cutout, its backwards and missing the proper insulators. I rebuild generators and refurbish original cutouts. I can provide you with a correct cutout. PM me if interested.
Steve
Looks ok to me why is it backwards?
 
ndnchf is correct. The battery closes the points and connects it to the generator (motor), which blows the fuse.

Question is, where did that generator case come from. Looks like you need to drill and tap new mounting holes. (Careful of the field windings.)
 
That’s a later generator that style just had 2 wires coming out of a grommet instead of the threaded post one for power out, the other is field ground or attached to the oval cutout.
That style reproduction cutout usually has burned up contacts or melted solder where the winding connects.
Turn the cutout around and make a short wire to connect it.
 