Polarizing 48 F1

CSPIDY

Member
I’m working on a 1948 F1 Pickup with a V8

Someone had previously switched the battery polarity to neg grid.

I have switched it back to pos grd, verified the coil is pos grd.
when it runs the amp meter moves to discharge

I would like to polarize the generator but not sure what procedure to follow
appears there are two types of generator systems

the wiring is all original, ick

Dave
 
If you have a B circuit, regular will show posts in this order B F A , UNHOOK field wire on reg & touch to battery post on reg, quickly

If A circuit, regular B A F USE A JUMPER from A to B
 
That’s the question
which type system do I have
 

Attachments

  • 24C71249-B8B4-436C-823E-90EE11A64F01.jpg
    24C71249-B8B4-436C-823E-90EE11A64F01.jpg
    66.6 KB · Views: 22
  • 46EF5012-060C-4C0E-AE28-83279ADF9BCF.jpg
    46EF5012-060C-4C0E-AE28-83279ADF9BCF.jpg
    66.3 KB · Views: 25
Found an old thread where rotorwrench explained it
Pulled the field wire from the generator
touched the field with battery power
Generator works as advertised
Thank you
 
Found an old thread where rotorwrench explained it
Pulled the field wire from the generator
touched the field with battery power
Generator works as advertised
Thank you


CSPIDY
Please share rotowrench's post explaining the difference as I urgently need this information! Thanks
 
Back