51woodie
Well-known member
I was out for an afternoon drive in my '46 Coupe, 59AB, and it began to run rough. Missing on acceleration, and not revving as it should. Time to go home! The next day, I pulled the distributor, and found the condenser was open when tested with the ohmmeter. I installed a condenser I had purchased from Tubman, on spec that I would need it one day. As I don't have a machine to test my distributer, I checked the point gaps, both at +/- .015", and installed the unit. Out of curiosity, I wanted to test the dwell to see what it was. Two question came up when I connected the leads from the dwell meter.
1. What is the correct dwell? I did searches and just got confused.
2. When I connect - to coil + to ground, I get 42 deg.
When I connect + to coil - to ground, I get 48 deg.
What should the dwell be, and why the difference when polarity on the connections are reversed?
Took the car for a test drive, and it runs like Henry built it. I sure wouldn't want to do a condenser change on the side of the road!
1. What is the correct dwell? I did searches and just got confused.
2. When I connect - to coil + to ground, I get 42 deg.
When I connect + to coil - to ground, I get 48 deg.
What should the dwell be, and why the difference when polarity on the connections are reversed?
Took the car for a test drive, and it runs like Henry built it. I sure wouldn't want to do a condenser change on the side of the road!