6V to 12V conversion

Last time I checked a higher coil discharge means a hotter spark..means a more efficient burn,means a cooler engine..that isn't a bad thing.So many modern improvements can be made to make the model A a more enjoyable and more efficient machine..without swapping out the basic components..its one of the few engines I've seen where you can basically double the horsepower in a day..
 
"While European cars were 12 volt from very early . . .."

My 1965 Volkswagen was 6 volts. I think the 1966 was still 6 volts, although I did not own a 1966, so I am not certain.

W. Michael
 
"While European cars were 12 volt from very early . . .."

My 1965 Volkswagen was 6 volts. I think the 1966 was still 6 volts, although I did not own a 1966, so I am not certain.

W. Michael

I have a 1928 Delage - 12 volts as were several others pf that era. VW was the exception over there but they eventually saw the light too.
 
"While European cars were 12 volt from very early . . .."

My 1965 Volkswagen was 6 volts. I think the 1966 was still 6 volts, although I did not own a 1966, so I am not certain.

W. Michael

!966 were still 6 volt, they went to 12 volt system in 1967.
 
I do not plan to convert mine, everything works well at 6V. However, I also see there would be advantages to running 12v neg gnd if you wanted to add accessories. Mine'll stay as is, but I certainly am not going to poo poo those who do convert theirs. I would question those who do the conversion to fix a problem they are having, if a starter or generator or wiring etc isn't cutting it at 6V, it won't be long it won't be cutting it at 12 V either.
 
I do not plan to convert mine, everything works well at 6V. However, I also see there would be advantages to running 12v neg gnd if you wanted to add accessories. Mine'll stay as is, but I certainly am not going to poo poo those who do convert theirs. I would question those who do the conversion to fix a problem they are having, if a starter or generator or wiring etc isn't cutting it at 6V, it won't be long it won't be cutting it at 12 V either.[/QUOTE


X2
 
I'm going to thread lightly here as I have just gotten my first "stock, non modified" early Ford. I have a couple of others, but they are V8, HotRodded and already converted to 12 volts. I have a stock 6volt, positive ground '30 coupe that I want to convert to 12 volts, and negative ground. I understand the 3ohm coil, that 6 volt wiring is compatible, need to change bulbs etc. what I don't understand is, if I change to negative ground, do I need to source a negative ground starter?? Won't the original positive ground one run reverse if it's hooked up on negative ground?? Maybe that was touched on, but I looked thru a couple of times but didn't see anything about that particular issue??
Thanks, Ken
 
And yes I've been a member/lurker here for info and learning since 2013, but that was my first post because most of my stuff is HotRods and I post those kind of things over on the HAMB.
 
I'm going to thread lightly here as I have just gotten my first "stock, non modified" early Ford. I have a couple of others, but they are V8, HotRodded and already converted to 12 volts. I have a stock 6volt, positive ground '30 coupe that I want to convert to 12 volts, and negative ground. I understand the 3ohm coil, that 6 volt wiring is compatible, need to change bulbs etc. what I don't understand is, if I change to negative ground, do I need to source a negative ground starter?? Won't the original positive ground one run reverse if it's hooked up on negative ground?? Maybe that was touched on, but I looked thru a couple of times but didn't see anything about that particular issue??
Thanks, Ken

No, the starter will turn in the same direction. They are not polarity sensitive. When I convert to 12v, I modify the starter so it doesn't kick as hard when it engages. The vendors have kits for that.
 