I have never had much luck with the telescoping two point inside gauges or mics. The problem I have experienced is consistency. When your looking for .0005 differences they are just not consistent enough (at least not when used by me, LOL).
I have never had much luck with the telescoping two point inside gauges or mics. The problem I have experienced is consistency. When your looking for .0005 differences they are just not consistent enough (at least not when used by me, LOL).
More info on bearing clearance. The machine shop that checked and assembled the crank and main bearings measured the OD of the crank with a mike, and the ID of the installed bearing & cap with bore gauge. They said the bore gauge was more accurate than plastigauge. Bore gauges are too costly to invest in where plastigauge is good enough.
I for one did not know this, which means that I have been doing it wrong for years. I will try this next time. Thank you. BillDon't believe what he said about, plastigauge, Mr. Russcc, or a bore Mic. he is wrong about both.
Many people do not know how to use plastigauge. They try to use it dry, and that will give you a bad reading. You have to use oil on the shaft, and bearing, or the plastigauge will NOT spread. With oil, you will get its full expansion, and, correct reading.
Thanks,
Herm.
Don't believe what he said about, plastigauge, Mr. Russcc, or a bore Mic. he is wrong about both.
Many people do not know how to use plastigauge. They try to use it dry, and that will give you a bad reading. You have to use oil on the shaft, and bearing, or the plastigauge will NOT spread. With oil, you will get its full expansion, and, correct reading.
Thanks,
Herm.
You are right Mr. JSWeery, telescoping gauges should never be used on anything, unless .002 thousandths is as close as you need.
The best, and most accurate, to a .000-10, of a thousandths, is a post mic, also called an inside Mic. You will get the same reading every time.
When you get it set, don't read the post Mic, but read the OD, of the post Mic, with an outside Mic.
We build bearings every day, and can't afford to be wrong, even once.
They make smaller ones also, that we use, and also other designs, that are a 3 leg type, spendee, but so are mistakes.
Last point, There has never been an instant, for us, in 54 years, that any kind of cylinder bore mike, reading, has been accurate enough, to read bearing sizes, or oil clearance, and there has been countless instances.
Thanks,
Herm.
Yeah, I've even seen it leave a small impression in the Babbitt layer in an insert when used dry.
Any thoughts on how much "drag" there should be on an inside mike when at the correct setting? This seems to be a variable for me.
Thanks
In order to effectively use a bore-gauge to check brg clearance you need one that does NOT use any type washers along with the mandrels to get to the size you need!
Thanks, Gary in N.Y.
P.S. There is absolutely no issues with using "Plastigage", it's good for checking when a gauge isn't available! There is one other method (also accurate) that hasn't been mentioned anywhere up here and I'm sort of surprised! We used it many, many, years ago to get 15 units per week out the door! We had no bore gauge at the time and still managed well! Maybe somebody here will figure it out???
Shim stock?
Doesn´t matter if it´s a sunnen or a mitutoyo diallbore gauge from precision or performance point of view...sunnen use the measuring finger and a lock nut to adjust the zero on the dialgauge...others use fixed fingers and adjust the height of the dialgauge.
Not sure why a boregauge with fixed fingers(washers) would be any less accurate...tell that to mitutoyo
For measuring inside a round hole and not just checking it against a std a 3-point micrometer is the way to go !
I spent so much on tools the last month I my need to go back to work,Lol
Lawrie
Tight is dangerous, a little loose is safe.
With looser clearances, as long as they are not excessive, you're a lot safer. Tight clearances are what spin bearings.
Good Luck