Two recent Koats post:
A quick easy test on the generator only. Join the Gen and Field wires together at the regulator but have them disconnected from the regulator. Connect an analogue DC voltmeter to the two connected wires (NEG voltmeter wire) and the POSITIVE voltmeter wire to ground. This is assuming your Ford is original POS ground. The scale on your meter needs to be 20 to 30 volts DC. Start engine and rev it up to 2000 RPM or so and the voltmeter reading should rise quickly to the end of the scale as the revs rise. IF volts are zero or low as in 6 volts or so then the generator is faulty. Its a bit hard using a digital multimeter set to DC volts to read this. An old analogue type voltmeter is best. Just do that test ONLY and report results. Regards, Kevi
Get your car hot and up to the point where it is not charging again, leave it running and disconnect the field wire, (middle one ) from the voltage regulator and move/connect it over to the Armature or Gen terminal. Rev engine up and read voltage at generator terminal of regulator which should go to 8 volts plus. This is providing the generator is Ok. We have bypassed the regulator field control here and the generator will charge flat out if it is working OK. If there is still a low voltage reading of 6.25 volts then the generator is faulty. If the voltage is 8 volts plus then the voltage regulator is faulty and requires attention. Also very important that all battery power connections and earths a good throughout the car. Check battery terminals, starter solenoid terminals, ammeter terminals, etc. Should be tight, clean and not getting hot to the touch during operation. Regards, Kevin.