Thanks everyone for the info. The battery was 5.8 and when I started the motor the generator was putting out 6.10. I was working on my turn signal's and that was why the battery was low.
I only use an analog meter for Model A checks. 5.8 would indicate a dead battery for all practical purposes. Is you meter correct and calibrated?
At least you do indicate the generator is charging.
TomAt 500 engine RPM a good generator should start to put out a hair more than battery voltage. Unless you install an electronic voltage regulator the voltage will be set by the battery, and adjusting the third brush will change the amps being pumped into the battery.
500 engine RPM gives the generator 750 RPM.
Tom
You said adjusting the third brush. What is the third Brush? Also do you have an electronic voltage regulator on yours?
Appears that the adjustable brush moves clockwise (in your photo) along the approx 90 degree arc between the output and ground brushes....yes?
Tom,
Is this like the Regulator that you have.
Model A Ford Generator Cut Out - Electronic Voltage Regulator Version - Ford Script - 6 Volt Positive Ground Only
http://htsmall.macsautoparts.com/assets/macs/images/size/265x265/sku/64-20675.jpg
... Has anyone thought about changing to a alternator.
Johnny