Hey guys, what is the amperage of the fuses that are used by the folks running electric 6 volt fuel pumps ? No information about what fuses to use came with the pump. The pump is a E8092 Airtex. Thanks. old guy.
Fuses are NORMALLY sized to protect the wire used in the circuit......NOT the device itself. DD
I just Rewired mine with a relay to battery side of solinoid. Used a 30 amp fuse.
Same fuel pump as yours. Btw I think you have a typo it's a 8902![]()
Fuses are NORMALLY sized to protect the wire used in the circuit......NOT the device itself. DD
Fuses are NORMALLY sized to protect the wire used in the circuit......NOT the device itself. DD
If you wired the pump into the main switch circuit correctly, would you really need a separate fuse for the pump?
Good info rotowrench, thanks. old guyWiring on the old pre-war 6-volt vehicles started out with no fuses at all to finally adding circuit protection for lighting and accessories. Cars in the model A era caught fire on occasion and burned up due to this. My Great Grandpop had an early Chevrolet car burn up back in the day and there wan't much left of it due to the high usage of wood in the structure. The lighting system was the most complicated electrical item in the post model A era until radios and heater blowers started to show up. The 6-volt systems needed larger wire gauge in order to efficiently transfer power due to higher resistance in smaller gauges. The larger the wire the larger the circuit protector. A 10 AWG wire conductor would need a minimum of a 30-amp in line fuse to protect it. A person can use a lower rated fuse but nothing higher then a 30. This is an abbreviated listing from an FAA Advisory Circular to give folks an idea of what the minimum fuse rating is for the size of American Wire Gauge conductors:
AWG = Fuse Rating
8 = 50-amp
10 = 30-amp
12 = 20-amp
14 = 15-amp
16 = 10-amp
18 = 10-amp
20 = 5-amp
There are different ratings for circuit breakers with AWG wire but these are more common in aviation so I won't list those. You can use a smaller fuse that is more protective of the load device but you can't use one any larger or the wire won't be properly protected from fire. If you ever see a wire burn from a short, you will know how quickly it happens and how much damage it can do. Wiring systems should be well dressed and protected from shorting against metal structure. A rats nest of old decrepit wiring is an accident waiting to happen.